MOOSE ZXSSD Podręcznik Użytkownika

Przeglądaj online lub pobierz Podręcznik Użytkownika dla Systemy kontroli dostępu bezpieczeństwa MOOSE ZXSSD. MOOSE ZXSSD User guide Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
ZX400/ZX410
SECURITY SYSTEM CONTROL
PROGRAMMING GUIDE
WWW.DIYALARMFORUM.COM
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - ZX400/ZX410

1ZX400/ZX410SECURITY SYSTEM CONTROLPROGRAMMING GUIDEWWW.DIYALARMFORUM.COM

Strona 2

10After entering programming mode, press the ‘2’ key for Set Clock programming. The Control Station will go into clock setmode.The SSD Control Statio

Strona 3

11While the Control Station is displaying the value at a location, you can enter digits to change the value at that location. Thenew value is display

Strona 4

12Key #1 0123456789: ; <=>?@Key #2 A B CKey #3 D E FKey #4 G H IKey #5 J K LKey #6 M N OKey #7 P Q R SKey #8 T U VKey #9 W X Y Z [ ù ] ^ _Key #0

Strona 5

13If the ENTER or CLEAR key is pressed and no changes have been made, the Control Station will return to the Zone IDprompt. If the CLEAR key is press

Strona 6

14To edit the Function Map, press the PROGRAM (9) key, enter the installer passcode, and press the ‘3’ key to select the EditFunction Map programming

Strona 7

15AWAY Exit Delay Time 0 to 255 secondsSTAY & NIGHT Exit 0 to 255 secondsTimeEntry Delay Time 1 0 to 255 secondsEntry Delay Time 2 0 to 255 second

Strona 8

16Enter For: 0123456789ABCDEFFirst DigitAll Features Below Disabled *Two Button Arm ********Double Button Press Arm * * * * * * * *Open After Alarm **

Strona 9

17KEYPAD 1 KEYPAD 2 KEYPAD 3 KEYPAD 4 KEYPAD 5 KEYPAD 6Loc Default Loc Default Loc Default Loc Default Loc Default Loc DefaultKeypad Type LED LED SSD

Strona 10 - WWW.DIYALARMFORUM.COM

183.2.3 Zone Data DescriptionsZone Type Area Expansion Zone Burglar Zone Attribute Zone AttributeLoc Default Loc Default Loc Default Loc Default Loc D

Strona 11

19Item Valid RangeZone Type 0 = Not Used1 = Burglar2 = 24 Hour Fire3 = 24 Hour Holdup4 = 24 Hour Auxiliary5 = Momentary Keyswitch (ArmAWAY/Disarm)6 =

Strona 12

2WWW.DIYALARMFORUM.COM

Strona 13

20Enter For: 0123456789ABCDEFFirst DigitStandard (all below disabled) *Chime Always ********Verifying * * * * * * * *Self-Verifying **** ****Sentry Te

Strona 14

21 Code Authority Level Operation Area Code Authority Level Operation AreaDefault Loc Default Loc Default Default Loc Default Loc DefaultUser 01 1234

Strona 15

22** For High Level Security applications onlyAccess from Keypad *********** **Chime Enable/Disable ***********Silence Bell without Disarm * * *Arm (

Strona 16

23This data block is used to assign the programmable outputs. The control is equipped with one programmable on-boardoutput (PGO1) and one bell output

Strona 17

24If the Output Condition is “Ready”, “Armed AWAY”, “Armed STAY”, “Armed NIGHT”, “Armed & Exit Time Expired”,“Exit Time”, “Entry Time”, “Annunciat

Strona 18

25Condition Output Becomes Active When:Fire Alarm A Fire or Verified Fire zone or an ‘A’ Key is in alarm.Fire Supervisory A zone defined as Fire Super

Strona 19

26The list of Trouble conditions are as follows:AC Power Failure Low Battery Memory ErrorCommunication Failure Silenced Fire Alarm Fire SupervisorySmo

Strona 20

27NOTE: If the First Digit entered is ‘1’, it must be entered as ‘01’. A = 10; B = 11; C = 12; D = 13; E = 14; F = 15System Attribute TableDelay Bef

Strona 21

28Used to enable the control digital communicator for eventreporting. Must be set to 0 if phone line is disconnected. If line isdisconnected and a t

Strona 22

29Location DefaultTelephone 1 (16 digits) [337 - 352] all F’sTelephone 2 (24 digits) [353 - 376] all F’sRPM/2 Pro Phone (16 digits) [377 - 392] all F’

Strona 23

3Table of ContentsOperating The System ...

Strona 24

30Item Valid Range DescriptionTelephone 1 Account No.Telephone 2 Account No.6 Hex Digits6 Hex DigitsAccount number used when dialing telephone #1. Se

Strona 25

31Fire Phone No.Note: These events are reportedusing Area 1 account codes only.Systems Events Phone No.Note: These events are reportedusing Area 1 acc

Strona 26

32Alarm Restore Bypass TroubleLoc Default Loc Default Loc Default Loc DefaultZone 01 [435] H-31 [436] H-E3 [437] H-AB [438] H-F3Zone 02 [439] H-32 [44

Strona 27

33Close Open Close OpenLoc Default Loc Default Loc Default Loc DefaultUser 01 [555] H-C1 [556] H-B1 User 26 [605] H-CF [606] H-BFUser 02 [557] H-C2 [5

Strona 28

34Loc Default Loc Default‘A’ Key Report Code [655] H-19 Comm Test Report Code [674] H-00‘B’ Key Report Code [656] H-29 AC Fail Report Code [675] H-FA‘

Strona 29

35Recent Closing Code 00 to FF Code sent in addition to a burglar alarm event if the alarm occurs within twominutes after exit time expires.Latchkey S

Strona 30

36Area 1 Area 2Location Default Location DefaultScheduled Arm Mode [693] 0 [726] 0Scheduled Arm Days [694] H-00 [727] H-00Arm Time Sun (hr:min)

Strona 31

37NOTE: If the First Digit entered is ‘1’, it must be entered as ‘01’. A = 10; B = 11; C = 12; D = 13; E = 14; F = 15Scheduled Arming and Latch Key

Strona 32

38Location DefaultInstaller Passcode [759 - 762] 9632Call 2 Timer (sec) [763] 0Auto Answer Ring Count [764] 5Enable RPM [765] 1Enable Power Up Program

Strona 33

39Note 1: Restarting Exit TimeIf an exit time is counting down from an AWAY arming, the exit time may be automatically restarted once to reduce fals

Strona 34

41Operating The System1.1 IntroductionThe Moose ZX400/ZX410 Security System incorporates the most desired operational features available today. The Z

Strona 35

40Note 6: Verifying or Self-Verifying Burglar ZonesIf an armed Verifying Burglar zone is violated, then a forty second Verification Timer is started.

Strona 36

41Note 10: Senior WatchThe Senior Watch attribute may only be used with Burglar, Critical Condition Monitor, Universal, and Universal Logged zones. I

Strona 37

42Note 12: Delay Before Dial TimeThe Delay Before Dial Time is used as the time that a user has after a Burglar, Holdup, or Auxiliary Alarm from a zo

Strona 38

43bus. The interface device will send an acknowledgment to the system upon successful transmission of an event. The telephone number willnot be used

Strona 39

44Event Type CID Code Event Source‘A’ Key Fire Alarm 1115 500 + Keypad (1 - 6)Zone Fire Alarm 1110 Zone (1 - 30)Zone Fire Supervisory 1200 Zone (1 - 2

Strona 40

45Zone Auxiliary Trouble Restore 3370 Zone (1 - 28)Zone Other Trouble Restore 3370 Zone (1 - 28)Senior Watch Trouble Restore 3641 Zone (1 - 28)Zone No

Strona 41

46UL has established certain requirements which pertain to the installation, use, and programming of this equipment. The local AuthorityHaving Jurisd

Strona 42

47IndexA‘A’ Key 17, 24, 25, 34, 44AC Cycles 27AC Power Failure 8, 26ACCESS Key 7Account Code 11, 33, 42Alarm Abort 27Alarm Indicator 24, 25, 26

Strona 43

48RREADY 4Receiver Compatibility 29Remote Connect 10, 22Remote Programming 8, 10, 38Report Code 12, 32, 33, 34, 35, 42, 46Reset Smoke Key 7RF Si

Strona 44

49NotesWWW.DIYALARMFORUM.COM

Strona 45

5FIGURE 1-1 System Control Stations1.3 Control Station OverviewFor SSD, LED, LCD, and VFD Control Stations:Away, Stay, and Night Keys These keys, f

Strona 46

50NotesWWW.DIYALARMFORUM.COM

Strona 47

51WWW.DIYALARMFORUM.COM

Strona 48

52sentrol controls groupPO Box 29041510 Tate Blvd. SEHickory, NC 28603Sales: 800.547.2556Fax: 503.691.7566Technical Support: 800.800.2027MOOSEa pro

Strona 49

6All Control Station function keys (except the View Info Key) require that the function key be pressed followed by a validpasscode. The passcode’s au

Strona 50

7KEY #6 CHIME KEYThis key turns the chime function on or off for a particular area.KEY #7 RST SMOKE KEYThis key resets all latched smoked detectors an

Strona 51

8The control may be divided (partitioned) into two independent areas. To the customer, each area appears to be a full-featured system. This allows o

Strona 52 - 64812702B

9Figure 2-1 Area PartitioningEach area can be programmed to control separate outputs with a dedicated audible or annunciator. It is also possible t

Komentarze do niniejszej Instrukcji

Brak uwag