26
The list of Trouble conditions are as follows:
AC Power Failure Low Battery Memory Error
Communication Failure Silenced Fire Alarm Fire Supervisory
Smoke Trouble Call RPM Failed Silenced Burglar Tamper
Missing Keypad Zone Trouble Zone Missing
Fire Trouble Telco Line Fault Bell Fault
RF Jamming RF Point Not Reporting RF Point Tampering
RF Point Low Battery
Key 6 Output ENTER + Key #6 is pressed on a keypad primary to its area. May be used to toggle an output ON/OFF.
RF Annunciator Reserved for future use.
Access by Keypad Any of its Control Stations have an Access timer that is running or ON. (See Section 3.3, Programming Note
18.)
Quick Access By Keypad Any of its Control Stations have a Quick Access timer that is running or ON. (See Section 3.3, Programming
Note 18.)
Zone Violated The zone is violated
Zone in Alarm or Senior Watch The zone goes into alarm. For a Burglar zone, it will deactivate when the alarm is silenced. For Fire, Holdup,
Auxiliary, Burglar Tamper, Verified Fire, and Fire Supervisory zones, it will deactivate when the zone restores
after the alarm has been silenced. The zone goes into Senior Watch Trouble until the condition restores (See
Section 3.3, Programming Note 10.)
3.2.6 Global System Options Description
Global System Options Default Table
Fire Cutoff Time 0 = No Cutoff,
1 to 255 minutes
Burglar Cutoff Time 0 = No Cutoff,
1 to 255 minutes
Holdup Cutoff Time 0 = No Cutoff,
1 to 255 minutes
Auxiliary Cutoff Time 0 = No Cutoff,
1 to 255 minutes
Universal Output Time 0 = Toggle ON,
1 to 255 seconds
Item Valid Range Description
The following table refers to programming locations 310 through 321:
Determines the time in minutes for Bell Output and Fire Alarm signaling device.
Determines the time in minutes for Bell Output and Burglar Alarm signaling
device.
Determines the time in minutes for Bell Output and Holdup Alarm signaling
device.
Determines the time in minutes for Bell Output and Auxiliary Alarm signaling
device.
Controls the timer for output programmed as Universal. Activated from Universal
or Universal Logged zones. (See Section 3.3, Programming Note 16.)
Time Time
Loc Default Loc Default
Fire Cutoff Time (min) [310] 0 AC Failure Delay (min)* [317] 30
Burglar Cutoff Time (min) [311] 10 Senior Watch Time (hrs) [318] 24
Holdup Cutoff Time (min) [312] 10 System Attributes [319] H-31
Aux Cutoff Time (min) [313] 10 Passcode Attempts [320] 8
Universal Output Time (sec) [314] 0 AC Cycles ** [321] 0
Delay Before Dial (sec) [315] 0
Fire Delay Before Dial (sec) [316] 0 * ODD = Silent, EVEN = Audible
** 0 = 60 Hz, 1 = 50 Hz