Note 6: Verifying or Self-Verifying Burglar Zones
If an armed Verifying Burglar zone is violated, then a forty second Verification Timer is started. If the timer expires and the zone that started
it is still in violation, then the zone’s violation is verified. If another armed Burglar zone is violated while the timer is still running, then that
violation verifies the first zone’s violation.
If an armed Self-Verifying Burglar zone is violated, then a forty second Verification Timer is started. If the Timer expires and the zone is still
in violation, then the zone’s violation is verified. If another armed Burglar zone is violated while the Timer is still running, then that violation
verifies the first zone’s violation. If the same armed Burglar zone is violated a second time while the Timer is still running, then the zone’s
violation is verified.
If the area is armed such that a violation from the zone would normally cause an instant alarm:
• when the zone is first violated, nothing happens.
• when the violation is verified, an instant alarm occurs.
• If the Verification Timer expires without the violation being verified, then nothing happens.
If the area is armed such that a violation from the zone would normally cause an Entry Time or Pre-Alarm Warning Time Delay:
• when the zone is first violated, the Delay Timer is started.
• if the violation is verified while the Delay Timer is still running, then the Delay Timer continues as normal.
• if the Verification Timer expires while the Delay Timer is still running and the violation has not been verified, then the time continues. If
the Delay Timer expires and no zones are violated from the Delay Time, then nothing happens.
• if the Delay timer expires before the Verification timer expires and the violation has not been verified, then nothing will happen until
either the violation is verified or the Verification Timer expires.
• if the violation is verified after the Delay Timer has expired, then an instant alarm occurs.
• if the Verification Timer expires after the Delay Timer has expired without the violation being verified, then nothing happens.
Note 7: Sentry Test Burglar Zones
If a Burglar zone has Sentry Test enabled, then each time the zone is disarmed, it must be tested before it can be armed again. A test consists
of violating the zone from a restored state and then restoring it again.
If the zone has not been tested, then it appears as a faulted zone, making its area not ready to arm. An untested zone cannot be armed. If the
zone is bypassable, then it may be bypassed to get around the testing. Force-Arming should not be enabled on systems with Sentry Test
Burglar Zones.
Note 8: Zone Activation of Bell Output and Keypad Sounders
The Bell Output on Alarm attribute determines whether the Bell Outputs for the zone’s area activate due to an alarm from the zone. It does not
affect the activation of any other programmable outputs, including an associated Alarm output. This attribute is only used if the Zone Type is
Burglar, Holdup, Auxiliary and 24 Hour Burglar Tamper, otherwise, it is ignored. The Bell Outputs activate on all alarms from Fire and
Verified Fire zones and from an ‘A’ key. They never activate from the other Zone Types.
The Keypad Sounder on Alarm attribute determines whether the Control Station sounders activate due to an alarm from the zone. It does not
affect the activation of any programmable outputs. This attribute is only used if the Zone Type is Burglar, Holdup and Auxiliary, otherwise,
it is ignored. Keypad sounders activate on all alarms from Fire and Verified Fire zones and from an ‘A’ key, as well as from 24-Hour Burglar
Tamper and Fire Supervisory zones. They never activate from the other Zone Types.
If a Holdup zone is programmed with neither Bell Output on Alarm nor Keypad Sounder on Alarm, then an alarm from the zone will be
invisible on the Control Stations.
Note 9: Bypassable Zones - Fire Trouble Condition
All zones may be programmed as Bypassable. If a Fire, Verified Fire or Fire Supervisory zone is bypassable and is bypassed, a Fire Trouble
condition occurs and is reported. The condition remains until the zone is unbypassed.
The Fire Trouble condition will also occur during a Walk Test.