38
Location Default
Installer Passcode [759 - 762] 9632
Call 2 Timer (sec) [763] 0
Auto Answer Ring Count [764] 5
Enable RPM [765] 1
Enable Power Up Program [766] 0
Lockout Local Program [767] 0
Item Valid Range Description
Installer Passcode 0000 to 9999 The installer passcode is the only passcode that may program the
entire Function Map. See Section 3.2.4 for a description of the
other functions that may be performed.
2nd Call Timer 0 - 255 seconds Time in seconds for the answering machine bypass time window.
This allows the remote programmer to bypass an answering
machine by making two calls to the premises. The first call must
ring three times or less and not be answered. The answering
machine bypass time window starts ten seconds after the last ring
of the first call. If the first ring of the second call occurs within the
answering machine bypass time window, the panel answers the
second call on the first ring. Remote Programming must be
enabled and Auto-Answer Ring count must be non-zero.
Auto Answer Ring Count 0 - 15 rings Sets the number of rings that must occur before the panel automati-
cally answers the telephone for operation with RPM/2 Pro. A ring
count of 0 disables automatic answering, but manual connection
may still be used. If Remote Programming is not enabled, then the
auto-answer ring count is ignored and the panel never answers.
Enable RPM 0 = No Enables operation of the control with the RPM/2 Pro package.
1 = Yes
Enable Power Up Program 0 = No A quick way to enter program mode upon power up. Pressing the
1 = Yes 9 key and entering “9999” within the first 60 seconds after power
up enters the control into Installer Level Programming mode.
Consider disabling this feature for anti-takeover.
Lockout Local Program 0 = No This is provided for anti-takeover protection. If it is enabled, the
1 = Yes installer passcode is limited as noted in Section 3.2.4. A user may
still be able to perform user level programming and RPM/2 Pro
will be fully operational. Do not enable this unless an RPM/2 Pro
account has been established for the control.
This section deals with the attributes of the Remote Programming Manager Software. Before programming the specific
functions, it is important to understand the following:
ABORT: During a remote programming session, the control is fully functional and can detect and annunciate alarms
locally. The control aborts a session with RPM/2 Pro to report alarm events.
DATALOCK: As a provision of anti-takeover, the control does not permit local programming of the account numbers
and telephone numbers, or the Restore Factory Defaults option to operate when an agency code has been established
and programmed by the RPM/2 Pro software. Other installer programming changes are still allowed. When the
Datalock (agency code) is set, the Control Station emits an error tone if any attempt is made to change an account
number or a phone number or to default the control.
3.2.14 Programming Options
The following table refers to programming locations 759 through 767: